Validation

What is Validation in Forensic  DNA lab and how it is applied?

DNA profiles are often used by forensic scientists and law enforcement, in order to provide evidence for prosecution or defense of an individual  in court.  This means that methods used by scientists in forensic DNA laboratories, must be able to produce even more accurate and robust results than a normal lab.
 Therefore Validation is required. In Forensic DNA , Validation is an approved set of quality assurance guidelines, used to verify that a specific instrument, measurement technique or software is able to produce precise, accurate and reproducible data. Validation is a very important factor of forensic laboratories. As it provides confidence that the analytical methods used in a forensic DNA laboratory, are able to produce valid results. Which can then be accepted in court by the judge and jury.



Developmental and Internal Validation

There are two main types of validation required in a forensic science laboratory. In order to implement and develop modern techniques, instruments and methodology, Developmental and Internal Validation is required. 


Developmental validation:

Developmental validation is a demonstration of accuracy, precision and reproducibility by the manufacturer, academic or government institution.

 "Developmental validation must therefore precede the use of a novel methodology for forensic DNA analysis. Peer-reviewed publication of the underlying scientific principle(s) of a technology is then required." 
[Scientific Working Group on DNA Analysis Methods (SWGDAM). 2016. FBI — Forensic Science Communications - July 2004. [ONLINE] Available at: https://archives.fbi.gov/archives/about-us/lab/forensic-science-communications/fsc/july2004/standards/2004_03_standards02.htm. [Accessed 07 November 2016].]

Before all newly developed instruments, methods, measuring techniques and sampling techniques are implemented. They must undergo developmental validation. The purpose of developmental validation is provide confidence in its quality and effectiveness. Which must be equal or greater than previously used technique. These Validation studies must then be sufficiently documented and under go a peer-reviewed publication, an exception to this is, when a public presentation at a scientific meeting or technical manual, demonstrates the effectiveness of such technique.  Developmental validation is needed to validate the methods that are used in labs today, and provides solid evidence for their superiority over previously used techniques.



Internal Validation:

Internal validation differs from developmental validation in that is carried out by each forensic DNA lab individually.
Its purpose is to demonstrate the reliability and limitations used by each individual lab.
This includes satellite laboratories, which must conduct validation procedures, independently of the main laboratory. Every change which could alter the results of a method, such as changing detection platforms, reagents, measuring or sampling techniques require internal validation.
 These validation studies must then be appropriately documented and should conclude in a set of documented quality assurances and parameters, which must be followed by all lab personnel. “The techniques should then be evaluated in the laboratory and among laboratories to ensure the consistency of results.” 

[Scientific Working Group on DNA Analysis Methods (SWGDAM). 2016. FBI — Forensic Science Communications - July 2004. [ONLINE] Available at: https://archives.fbi.gov/archives/about-us/lab/forensic-science-communications/fsc/july2004/standards/2004_03_standards02.htm. [Accessed 07 November 2016].]


 

Validation Recomendations...


 ISO/IEC 17025:2005 specifies the general requirements for validation of competence to carry out techniques, tests, calibrations and sampling methods used in labs. ISO/IEC “17025:2005 is applies to all organizations performing tests or calibrations.” http://www.iso.org/iso/catalogue_detail?csnumber=39883
One of the requirenments of ISO/IEC 17025:2005 is that all methods and techniques must be validated. Therefore a set of recommendation have been put into place by the ENFSI Working Group, upon an agreed minimum standard of validation which is put into place by a lab. According to the ISO/IEC 17025:2005 paper
itself, the general recommendations for correct validation in Forensic DNA laboratory are as follows:
  • In order for a specific parameter to be validated, at least 5 samples must be analysed producing precise results. Note: this does not include negative control.

  • Proficiency samples should be taken into account when carrying out validation.

  • In cases where calibration settings or performance of an instrument is altered by factors such as maintenance, relocation or repair. Internal Validation is necessary.

  • The main objective of validation must show that new parameters are of same or better quality than the previous ones.
More detailed information on Validation can be found in the original document at http://www.iso.org/iso/catalogue_detail?csnumber=39883
Powered by Create your own unique website with customizable templates.
  • Home
  • Proficiency Testing
    • Importance
    • Potential Benefits
    • Processes involved
    • Test Providers/Tests performed
    • Accreditation
    • Schemes
  • Validation & Calibration
    • Validation
    • Calibration
  • Analytical Techniques
    • DNA Extraction
    • DNA Quantification
    • PCR
    • Capillary Electrophoresis
  • Evidence Control
    • Contamination control
    • Chain of Custody
    • Sample Storage
  • References